>
产品中心 >
leicabiosystems >
Vivantechnologys/ViPrimePLUS一步法AtTaq RT qPCR MasterMix(热启动)/150个反应/QLMM03
DescriptionViPrimePLUS One Step AtTaq RT-qPCR Master Mix is next generation first choice mix designed for fast and easy one step real-time PCR reaction set up. The improved formulation of master mix contains unique thermostable M-MULV enzyme, Hot Start Taq DNA Polymerases as well as MgCl2 and buffer components at optimal concentrations. The M-MULV enzyme has an optimal operating temperature of 55°C, and has a higher affinity for primer template duplexes which allows very rapid processing during RT step. The One Step AtTaq RT-qPCR Master Mix is designed to achieve excellent results in reaction efficiency, correlation coefficient and slope.ViPrimePLUS One Step AtTaq RT-qPCR Master Mix can be used to amplify any RNA template including mRNA, total RNA and viral sequences. The improved formulation of RT-qPCR master mix can detect extremely low copy number targets very specifically with high efficiency that gives CT values close to the theoretical time of detection. The ViPrimePLUS One Step AtTaq RT-qPCR Master Mix is a complete system for use in one step real-time PCR, the removal of a separate reverse transcription step reduces handling errors as well as the time taken to obtain results. The formation of primer dimers and non-specific products is prevented leading to optimum sensitivity and specificity..ViPrimePLUS One Step AtTaq RT-qPCR Master Mix has several formulations optimized to be used with most of real-time PCR instruments. The improved sensitivity and consistency of ViPrimePLUS One Step AtTaq RT-qPCR Master Mix in standard cycling conditions gives the industry leading performance in fast cycling conditions.
ApplicationsAll kinds of RNA sample material suited for RT-qPCR amplification can be used.
Features
- One step real time RT-qPCR reaction set up
- Equipped with thermostable M-MULV enzyme and Hot Start Taq DNA Polymerases
- Reliable quantification of extremely low copy number targets
- Optimal performance for highly sensitive and specific RT-qPCR reaction
- Compatible with most of the real-time PCR platforms
Component3 x 0.6ml aliquots of master mix 0.6ml aliquots of “no RT control master mix standard”
StorageStable at -20°C up to the expiry date stated. Store all components at -20°C upon arrival. Keep in aliquot to reduce freeze-thaw cycles.
Quality ControlAs part of the ISO9001:2008 quality assurance systems, each lot of ViPrimePLUS One Step AtTaq RT-qPCR Master Mix has been tested against predetermined specifications to ensure consistent product quality and highest levels of performance and reliability.
Limitation Of UseFor research use only. Not recommended or intended for diagnosis of disease in humans or animals. Do not use internally or externally in humans or animals.
InstrumentsTo calibrate a real-time PCR reaction, various formulations of master mixes are available for most of the platforms.
Product Description | Compatible Hardware |
QLMM03ViPrimePLUS One Step AtTaq RT-qPCR Master Mix | Biometra qTower, BioRad iCycler, BioRad IQ4, BioRad IQ5, Cepheid SmartCycler®, Eppendorf Mastercycler, Fluidigm BioMark™, Illumina Eco, MJ Chromo4, Opticon, PCRMax Eco™, Roche lightcycler® 480, lightcycler® LC96 and lightcycler® Nano Platforms, RotorGene, Roche Capillary Lightcycler 1.0-2.0, Stratagene MX MX4000P®, MX3000P®, MX3005®, Thermo PikoReal™ |
QLMM03-LRViPrimePLUS One Step AtTaq RT-qPCR Master Mix with Low ROX | Applied Biosystems 7500 and 7500 FAST platform, QuantStudio™, ViiA7 |
QLMM03-RViPrimePLUS One Step AtTaq RT-qPCR Master Mix with ROX | Applied Biosystems 7000, 7300, 7700, 7900 and 7900HT FAST platforms, GeneAmp® 5700, StepOne™, StepOne™ PLUS |
Ordering Information
Catalog No | Description | Pack Size |
QLMM03 | ViPrimePLUS One Step AtTaq RT-qPCR MasterMix | 150 reactions |
QLMM03-LR | ViPrimePLUS One Step AtTaq RT-qPCR MasterMix with Low ROX | 150 reactions |
QLMM03-R | ViPrimePLUS One Step AtTaq RT-qPCR MasterMix with ROX | 150 reactions |
DownloadManual
ViPrimePLUS One Step AtTaq RT-qPCR MasterMix ViPrimePLUS One Step AtTaq RT-qPCR MasterMix with Low ROX ViPrimePLUS One Step AtTaq RT-qPCR MasterMix with ROX
PublicationThis Product Has Been Used In:Attaran, B., Falsafi, T. (2017). Effect of biofilm formation by clinical isolates of Helicobacter pylori on the efflux-mediated resistance to commonly used antibiotics, . World Journal of Gastroenterology, Vol. 23, No. 7. 1163-1170 (2017).